Electrical installation
Warning! Only a qualified person must
do the electrical installation.
The manufacturer is not responsible if
you do not follow safety precautions
from the chapter "Safety information".
This appliance is supplied without a main
plug or a main cable.
Cable
Cable types applicable for installation or re-
placement: H07 RN-F, H05 RN-F, H05
RRF, H05 VV-F, H05 V2V2-F (T90), H05
BB-F.
For the section of the cable refer to the total
power on the rating plate.
Connecting the terminal board
The appliance has a six-pole terminal
board. The jumpers (bridges) are set for op-
eration on a 400 V three-phase with a neu-
tral wire.
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
123
4
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different, rearrange
the jumpers on the terminal board (refer to
the connection diagram below). Connect
the ground cable to the terminal. After you
connect the supply cable to the terminal
board, attach it with a junction clamp.
12345
12345
12345
12345
230V 3~
230V 1~
400V 2N~
400V 3N~
L1
L1 N
L2
L1 N
N
L2
L3
L1
L2
L3
PE
PE
PE
PE
ENVIRONMENT CONCERNS
The symbol on the product or on its
packaging indicates that this product may
not be treated as household waste. Instead
it should be taken to the appropriate
collection point for the recycling of electrical
and electronic equipment. By ensuring this
product is disposed of correctly, you will
help prevent potential negative
consequences for the environment and
human health, which could otherwise be
caused by inappropriate waste handling of
this product. For more detailed information
about recycling of this product, please
contact your local council, your household
progress 41
Commenti su questo manuale